If you purchase this report now and we update it in next 100 days, get it free!
Market Insights The regional regulatory framework for solar street lights varies across major markets, creating distinct market-entry requirements beyond international IEC standards. In Saudi Arabia, SASO 2927:2019/AMD2:2023 establishes energy-efficiency, functionality, and labelling requirements, supported by SASO IECEE recognition, a CB test report, a SABER product certificate, and a shipment certificate before customs clearance. It also mandates IP66 for street-lighting products within its scope. India follows the BIS IS 10322 series, with IS 10322 (Part 5/Section 3) covering road and street-lighting luminaires. The revised IS 10322:2026 series was issued with implementation guidelines in March 2026, with a transition deadline of 2 August 2026 for the previous edition. China applies GB/T 24907-2010 for LED road-lighting performance and GB/T 19064-2025 for off-grid solar photovoltaicpower supply systems, which explicitly includes solar street lights and emergency lighting as reference applications. Battery compliance adds another market-access requirement: IEC 62619 covers industrial lithium battery safety, while UN 38.3 establishes mandatory transportation tests covering vibration, thermal cycling, shock, altitude simulation, external short circuit, impact, overcharge, and forced discharge. Manufacturers must also maintain the required UN 38.3 test summary and MSDS documentation to avoid freight rejection. Consequently, suppliers serving multiple countries must manage separate national approval files alongside battery safety and transportation records.
Competition in the solar street lighting market is increasingly determined by system-level certification, battery engineering, and optical performance. The certification portfolio is a primary entry barrier because individual standards address different product requirements. IEC TS 62257-9-8 and IEC TS 62257-9-5 address system quality and performance, IEC 62619 and UN 38.3 cover battery safety and transportation, IEC 60529 establishes ingress protection, and IEC 62262 covers impact resistance. These must be complemented by national requirements such as SASO 2927, BIS IS 10322, and GB/T 24907. Battery chemistry further differentiates suppliers, with LiFePO₄ widely preferred for municipal applications due to its thermal stability and cycle life commonly exceeding 2,000 cycles, compared with the higher energy density but greater thermal-management requirements of NMC and NCA batteries. Procurement documentation may include UN 38.3 test summaries, MSDS, IEC 62619 battery safety evidence, IEC 61215 and IEC 61730 PV module certification, and IEC 60598-1 and IEC 60598-2-3 luminaire compliance. Optical engineering and intelligent controls provide another competitive advantage, particularly in jurisdictions enforcing Dark Sky requirements. Full-cutoff optics, downward light distribution, and CCT ratings of 3000K or below are important specification criteria, while environmentally sensitive areas in Bloomington, Indiana, and Amador County impose more restrictive limits of 2200K or lower within designated zones. Timers, motion sensors, and photocell-based controls further support compliance.
What's Inside a Bonafide Research`s industry report?
A Bonafide Research industry report provides in-depth market analysis, trends, competitive insights, and strategic recommendations to help businesses make informed decisions.
Market DynamicsDriver: IEC TS 62257-9-8 quality requirements and national tender specifications converting the system into a documented-performance procurement
• IEC TS 62257-9-8:2025 and the national street-lighting standards have converted solar street lights from a price-driven commodity into a documented-performance procurement in which the buyer evaluates run-time, light output, and battery safety rather than rated wattage.
• The standard’s quality requirements are evaluated through the IEC TS 62257-9-5 test methods, which specify the full-battery run-time test, the solar run-time test, and the energy-service calculation, and the standard’s scope expressly covers products with a PV module peak power at or below 350 W and a system voltage at or below 35 V, which is the range in which the majority of stand-alone solar street lights are specified.
• The Indian framework reinforces the documentation requirement because the solar street light must be registered to IS 10322 (Part 5/Section 3) and the luminaire must be tested for all type tests as per the standard, while the Saudi framework requires the SASO IECEE recognition certificate resting on a CB test report plus the SABER product certificate and shipment certificate before customs clearance, which means the product cannot enter the country without the certification file.
• The consequence is that a tender evaluation is increasingly a file review rather than a product demonstration, and a supplier that cannot produce the IEC TS 62257-9-5 test report, the UN 38.3 summary, and the SASO or BIS registration is excluded before the price is opened.
Challenge: Battery transport and safety documentation as the binding constraint on cross-border supply
• The principal constraint on solar street light market access is not the PV panel or the luminaire but the battery documentation, because lithium batteries trigger transport and safety requirements that can stop a shipment before it reaches the project site.
• UN 38.3 is the mandatory transport test for lithium cells and batteries, covering vibration, thermal, shock, altitude, external short circuit, impact, overcharge, and forced discharge, and a battery that lacks a UN 38.3 test summary and MSDS can be refused by a freight carrier outright.
• IEC 62619 adds the industrial-safety requirement for the lithium pack, and the Australian product-safety regulator requires demonstrable compliance with either IEC 62133 for portable applications or AS IEC 62619 for industrial applications, which indicates that the pack-level evidence is a market-access condition in multiple jurisdictions rather than a single export formality.
• The chemistry choice compounds the documentation burden because LiFePO₄ is preferred for municipal projects on safety grounds, but a supplier that offers only NMC or NCA packs faces a higher thermal-risk profile and a more demanding BMS requirement, and a lead-acid option avoids the lithium transport rules but loses the cycle life and energy density that the run-time requirement demands.
• The national-standard fragmentation adds a second constraint because India’s IS 10322:2026 transition date of 2 August 2026 and the Saudi SASO 2927 IP66 mandate fall on different schedules, and a manufacturer serving both markets must run two recertification programmes for the same system rather than a single update.
Trend: Smart-city integration and Dark Sky spectral compliance shifting the value from the panel to the controls and optics layer
• Solar street lights are migrating from standalone dusk-to-dawn units toward smart-city nodes and Dark Sky-compliant optical systems, and the product evidence shows that the competitive frontier is the controls and optics layer rather than the PV panel’s wattage.
• The smart-city trend is visible in the integration of environmental sensors, traffic monitoring, public Wi-Fi, and electric-vehicle charging points into the solar street light, which the Asian market analysis identifies as a higher-value contract and long-term service revenue opportunity alongside the retrofit and replacement market for early-generation units installed between 2015 and 2020.
• The Dark Sky trend is visible in the ordinances that require 3000K or lower CCT and full-cutoff construction, with Bloomington, Indiana adding a 2200K or lower requirement within 500 feet of environmentally sensitive areas and requiring adaptive controls such as timers, motion sensors, or photocell-activated switches for publicly owned lighting.
• The competitive value is shifting from the panel and battery sizing to the control platform’s interoperability, the optical distribution’s cutoff performance, and the spectral compliance with the local ordinance, because a solar street light that meets the run-time requirement but violates the Dark Sky CCT or shielding rule is excluded from the project regardless of its energy performance.
Make this report your own
Have queries/questions regarding a report
Take advantage of intelligence tailored to your business objective
Reecha Roy
Research Analyst
Segmentation AnalysisBy System Type
• Standalone solar street lights constitute the volume backbone of the category because they operate independently of the grid and are the specification default for rural roads, remote highways, and areas where the grid connection cost exceeds the system cost, and their certification follows the IEC TS 62257-9-8 quality framework alongside the IEC 62619 and UN 38.3 battery evidence.
• Grid-connected solar street lights use the solar system as a supplementary source while remaining connected to the grid, and their certification adds the grid-interconnection and islanding-prevention requirements, with the Indian IS 16169:2019 utility-interconnected photovoltaic inverter islanding-prevention test procedure being the relevant standard in that market.
• Hybrid solar street lights combine solar, battery, and grid or generator input, and they are the specification choice where the grid is available but unreliable, with the certification covering both the off-grid and grid-connected modes and the hybrid controller’s transition behaviour.
By Product Configuration
• All-in-one configurations integrate the PV panel, battery, controller, and LED into a single housing, and they are the dominant configuration in the Asian market with a share expected to rise to 60–65% by 2035, because the integrated format reduces the installation labour and the risk of component mismatch, while the thermal management of the battery inside the housing becomes the binding engineering constraint.
• All-in-two configurations separate the PV panel from the lamp and battery housing, and they are used where the panel orientation and the lamp position cannot be co-located, with the split reducing the thermal load on the battery but adding the wiring and connector reliability requirement.
• Split-type systems place the panel, battery, controller, and luminaire in separate locations, and they are the specification for high-power and high-mast applications where the component sizing cannot be integrated, with the certification covering the interconnection and the voltage-drop performance across the separated components.
By Battery Type
• Lithium-ion batteries, particularly LiFePO₄, are the preferred chemistry for municipal solar street lights because of their thermal stability, lower risk of oxygen-driven combustion, and high cycle life of 2,000-plus cycles, and their certification requires the IEC 62619 industrial-safety evidence alongside the UN 38.3 transport test and the MSDS.
• Lead-acid batteries, including flooded, AGM, and gel variants, are less prone to thermal runaway than lithium chemistries but have a shorter cycle life and a lower depth of discharge, and they avoid the lithium transport rules while requiring the lead-recycling documentation that the EU Battery Regulation imposes.
• Other battery types, including nickel-metal hydride and emerging sodium-based chemistries, occupy a niche where the temperature range or the cycle-life requirement falls outside the lithium and lead-acid envelopes, and their certification follows the applicable IEC secondary-battery safety standard rather than the lithium-specific 62619.
Don't pay for what you don't need. Save 30%
Customise your report by selecting specific countries or regions
By Power Rating
• Below 30 W systems serve residential streets, pathways, and low-traffic rural roads where the illuminance requirement is modest, and the sub-30 W segment is where the all-in-one configuration and the integrated battery are most common.
• 30–60 W systems constitute the volume core of the municipal market because they cover the standard residential and collector road illuminance requirement, and this band is where the IEC TS 62257-9-8 350 W PV limit and the SASO 2927 IP66 requirement are most directly applied.
• 61–100 W systems serve arterial roads and public spaces where a higher illuminance and uniformity are required, and the thermal management of the battery and the LED becomes the binding constraint because the higher output increases the heat load inside the housing.
• Above 100 W systems serve highways, high-mast installations, and large public spaces, and they are the segment where the split-type configuration and the separate battery enclosure are specified to manage the thermal and weight constraints.
By Application
• Highways are the most demanding application because the illuminance and uniformity requirements are set by the road authority’s standard, and the system must satisfy the IEC TS 62257-9-8 run-time requirement alongside the national standard and the Dark Sky CCT cap.
• Urban roads use solar street lights where the grid connection is constrained or where the municipality is pursuing a renewable-energy target, and the specification is shaped by the local ordinance’s CCT and shielding requirements.
• Rural roads are the largest volume application for standalone systems because the grid connection cost is prohibitive, and the Indian and Chinese rural electrification programmes are the primary demand drivers. Residential streets use lower-power all-in-one systems where the illuminance requirement is modest, and the Dark Sky residential zoning requirements are most directly applied.
• Public spaces, including parks and plazas, use solar street lights with adaptive controls, and the 2200K or lower requirement within 500 feet of environmentally sensitive areas is the specification constraint.
• Industrial areas use higher-power and split-type systems where the area illuminance requirement and the security function determine the specification.
By End User
• Government and municipalities are the largest end-user segment because they own the road network and they are the entity that enforces the IEC, BIS, GB, and SASO standards, and the tender documentation is where the certification file is verified before the contract is awarded.
• Infrastructure developers use solar street lights in greenfield road and township projects where the grid is not yet available, and the procurement is shaped by the project lender’s technical specification rather than by a single national standard.
• Commercial and industrial operators use solar street lights for private roads, logistics parks, and industrial campuses, and the specification is driven by the internal security and sustainability requirement alongside the local authority’s CCT and shielding rules where the private road connects to the public network.
Regional Analysis • Saudi Arabia and the Gulf operate under SASO 2927:2019/AMD2:2023, the energy-efficiency, functionality, and labelling standard for street lighting, with the market-access route requiring the SASO IECEE recognition certificate resting on a CB test report, the SABER product certificate, and the shipment certificate, and with IP66 mandated for street-lighting products within the standard’s scope, alongside IEC 62619 and UN 38.3 for the lithium pack.
• India operates under the Bureau of Indian Standards IS 10322 (Part 5/Section 3) for road and street lighting luminaires, with the revised IS 10322:2026 series issued with implementation guidelines in March 2026 and a transition date of 2 August 2026, and with the IS 16169:2019 islanding-prevention test procedure applying to grid-connected inverters, while the Domestic Content Requirement for solar cells and modules in government projects adds a local-content dimension to the procurement.
• China operates under GB/T 24907-2010 for the performance requirements of LED lamps for road lighting and GB/T 19064-2025 for off-grid solar photovoltaic power supply systems, with the 2025 edition explicitly naming solar street lights as a reference application and the Cybersecurity Law and draft data-protection rules imposing restrictions on the data collected by smart street-lighting systems.
• Southeast Asia operates under national standards such as SNI 7391 in Indonesia, alongside the TKDN local-content requirement that mandates 30–60% domestic component sourcing in government projects, and the standards harmonisation across ASEAN remains gradual.
• Sub-Saharan Africa and donor-funded markets reference IEC TS 62257-9-8 and IEC TS 62257-9-5 as the quality benchmark because the World Bank and regional development banks use the IEC framework as the technical specification for off-grid lighting procurement, and the UN 38.3 and MSDS documentation is a shipment precondition for the lithium battery.
• Europe applies the CE marking under the Low Voltage Directive, EMC Directive, and RoHS, alongside IEC 60598-1 and IEC 60598-2-3 for the luminaire and IEC 62619 for the industrial lithium battery, with the Dark Sky 3000K and full-cutoff requirements adopted in a growing number of municipal lighting policies.
Considered in this report
• Historic Year: 2020
• Base year: 2025
• Estimated year: 2026
• Forecast year: 2031
Aspects covered in this report
• Global Solar Street Lights Market with its value and forecast along with its segments
• Various drivers and challenges
• On-going trends and developments
• Top profiled companies
• Strategic recommendation
By System Type
• Standalone Solar Street Lights
• Grid-Connected Solar Street Lights
• Hybrid Solar Street Lights
By Product Configuration
• All-in-One
• All-in-Two
• Split-Type Systems
By Battery Type
• Lithium-Ion
• Lead-Acid
• Other Battery Types
By Power Rating
• Below 30W
• 30–60W
• 61–100W
• Above 100W
By Application
• Highways
• Urban Roads
• Rural Roads
• Residential Streets
• Public Spaces
• Industrial Areas
By End User
• Government & Municipalities
• Infrastructure Developers
• Commercial & Industrial Operators
One individual can access, store, display, or archive the report in Excel format but cannot print, copy, or share it. Use is confidential and internal only. License information
One individual can access, store, display, or archive the report in PDF format but cannot print, copy, or share it. Use is confidential and internal only. License information
Up to 10 employees in one region can store, display, duplicate, and archive the report for internal use. Use is confidential and printable. License information
All employees globally can access, print, copy, and cite data externally (with attribution to Bonafide Research). License information