If you purchase this report now and we update it in next 100 days, get it free!
Market Insights KNX has established itself as an internationally recognised standard for building automation and lighting control, with interoperability and product certification forming the foundation of its ecosystem. Approved as ISO/IEC 14543-3, CENELEC EN 50090, CEN EN 13321-1, Chinese GB/T 20965 and ANSI/ASHRAE 135, the protocol supports building-control applications across Europe, China and the United States without relying on a single manufacturer's proprietary technology. Product certification is managed by the KNX Association and verifies conformity with KNX specifications, compatibility with products from other manufacturers and the use of a certified KNX stack. Testing is conducted through sixteen KNX-accredited laboratories worldwide. Manufacturers must register their products and complete testing within six months of registration. The certification process also requires ISO 9001 compliance, conformity with EN 50090-2-2 for EMC, electrical safety and environmental aspects demonstrated through an EC declaration, and successful KNX interworking tests covering standardised data types and optional function blocks. The KNX mark confirms that the product has completed the required conformity assessment and supports interoperability with KNX-certified devices from more than 450 manufacturers. Building regulations and cybersecurity requirements further influence the adoption of KNX lighting-control solutions. The EU Energy Performance of Buildings Directive 2024, Article 13(12), requires suitably zoned automatic lighting controls capable of occupancy detection. It also requires non-residential buildings with heating, air-conditioning or combined systems above 290 kW to implement building automation and control systems, with the threshold reducing to 70 kW by the end of 2029. Although lighting capacity does not contribute to these thresholds, buildings exceeding them because of HVAC capacity must also implement automatic lighting controls in their non-residential areas.
In the United States, ASHRAE 90.1-2025 strengthens lighting-control provisions through expanded daylight-responsive controls near windows and skylights, stricter automatic shutoff requirements, clearer sensor-placement and override guidance, and more granular control zoning. The specified zoning limits are 2,500 square feet in smaller spaces and 10,000 square feet in larger spaces. Cybersecurity is another consideration for connected KNX installations. The UK's Product Security and Telecommunications Infrastructure (PSTI) Regulations 2023 require connectable KNX gateways and IP interfaces to meet three core security requirements derived from ETSI EN 303 645. Manufacturers must publish a statement of compliance specifying the product's support period and vulnerability-reporting contact. At the protocol level, KNX Secure, standardised under EN 50090-3-4 and EN 50090-4-3, uses AES 128 CCM encryption according to ISO 18033-3 to strengthen communication security within KNX installations. Supplier competitiveness in the KNX products and lighting-control market depends on certification depth, access to accredited testing facilities and the ability to meet regulatory requirements across multiple geographical markets. These factors influence product eligibility, certification timelines and the range of building-control projects that manufacturers can serve. Certification portfolio and testing scope determine the level of technical evidence available for individual products. KNX certification is device-specific, with different testing categories covering interworking and functionality, protocol-stack and lower-layer conformity, and physical-layer performance. While basic certification demonstrates interoperability and functionality, additional stack-level and physical-layer testing provides evidence of protocol implementation and communication performance. This distinction becomes important in larger installations requiring reliable communication across extended bus runs.
What's Inside a Bonafide Research`s industry report?
A Bonafide Research industry report provides in-depth market analysis, trends, competitive insights, and strategic recommendations to help businesses make informed decisions.
Access to accredited laboratories is another competitive consideration. Only sixteen laboratories worldwide are authorised to conduct KNX certification testing. These facilities must meet ISO/IEC 17025 or ISO 9001 requirements covering testing operations, maintain qualified engineers through the KNX Test Engineer examination and undergo periodic surveillance audits. The limited number of testing facilities concentrates certification capacity, making laboratory availability an important factor in product-launch planning and certification lead times. Regional conformity requirements influence manufacturers' ability to sell the same product across international markets. European products must carry CE marking and demonstrate conformity with EN 50090-2-2. In China, manufacturers must address GB/T 20965 alongside applicable CCC or CQC electrical-safety requirements. Products sold in India must meet BIS registration requirements for the electrical portion, while connectable gateways marketed in the United Kingdom require a PSTI statement of compliance referencing ETSI EN 303 645. Managing these separate conformity requirements creates additional documentation and maintenance obligations for manufacturers serving multiple regions.
Market DynamicsDriver: EPBD BACS mandates and KNX certification converting lighting control into a code-compliance component
• The EPBD 2024 BACS requirements and the KNX certification framework have converted KNX lighting control from a specification preference into a code-compliance component whose installation is a condition of building performance compliance rather than a discretionary upgrade.
• The EPBD requires non-residential buildings above 290 kW to have BACS and automatic lighting controls, and the threshold drops to 70 kW by 2029, with the automatic lighting controls required to be suitably zoned and capable of occupancy detection under Article 13(12).
• ASHRAE 90.1-2025 reinforces the same direction in the United States market by expanding daylight-responsive controls, strengthening automatic shutoff, and requiring more granular control zoning, which means a lighting control system that cannot deliver zone-level occupancy and daylight response is excluded from code-compliant design regardless of its protocol.
• The KNX certification provides the interoperability evidence that a multi-vendor installation requires, because the KNX mark certifies that the device has passed the accredited test centre’s interworking tests against standardised data types, and the certification is the document that the specifier uses to justify the system’s ability to deliver the zoned control that the code assumes.
Challenge: Test-lab capacity concentration and the certification-scope non-equivalence
• The principal constraint on KNX product market access is that the certification capacity is concentrated in sixteen accredited laboratories worldwide, and the scope of the certification is not equivalent across products even when the KNX logo appears on both.
• The KNX Association distinguishes between basic interworking and functionality testing, stack and lower-layer testing, and physical-layer testing, and a device certified only for the basic category has not demonstrated the stack-level or physical-layer conformance that a large installation may require, which means a specifier who reads only the KNX logo cannot distinguish the certification scope without checking the certificate’s detailed test report.
• The laboratory accreditation requirements compound the capacity constraint because a laboratory must hold ISO/IEC 17025 or ISO 9001 covering testing operations, and its test engineers must pass the KNX Test Engineer exam covering specific volumes of the KNX standard for each accreditation category, which means the testing capacity cannot be expanded quickly in response to demand.
• The regional conformity fragmentation adds a second constraint because the same device must satisfy the KNX certificate, the CE marking, the Chinese GB/T 20965 and CCC requirements, the Indian BIS registration, and the UK PSTI statement, and the files are issued by different bodies and updated on different schedules, which multiplies the administrative burden for a supplier serving multiple markets.
Make this report your own
Have queries/questions regarding a report
Take advantage of intelligence tailored to your business objective
Reecha Roy
Research Analyst
Trend: KNX Secure and IP-based interfaces shifting the competitive frontier from the bus device to the secure gateway
• KNX lighting control is migrating from twisted-pair bus devices toward IP-based interfaces and KNX Secure gateways, and the product evidence shows that the competitive frontier is the secure gateway rather than the individual actuator.
• KNX Secure is standardised under EN 50090-3-4 and EN 50090-4-3 and uses AES 128 CCM encryption according to ISO 18033-3, which means the protocol itself provides end-to-end protection against eavesdropping and manipulation, and the KNX Association has incorporated KNX Secure testing into the accredited laboratory scope.
• The UK PSTI regime reinforces the shift because a connectable KNX gateway must comply with the three core ETSI EN 303 645 requirements, and a KNX Secure gateway that already implements encrypted communication and secure commissioning can satisfy the PSTI statement of compliance more readily than a gateway that relies on the building’s network firewall alone.
• The IP/Ethernet communication medium is the carrier for this shift, because the KNX IP router and IP interface are the devices through which the KNX installation connects to the building management system and the wider network, and the competitive value is moving from the actuator’s switching capacity to the gateway’s security architecture and its ability to expose KNX data to higher-level systems without compromising the bus.
Segmentation AnalysisBy Product Type
• KNX switches and actuators constitute the volume core of the lighting-control installation because they are the devices that physically switch and dim the luminaires, and their certification follows the interworking and functionality route with the application program tested against the standardised data types.
• KNX dimmers are a specialised actuator category because the dimming curve, the minimum load, and the compatibility with the luminaire’s driver determine whether the device can deliver the continuous dimming that ASHRAE 90.1-2025 and the EPBD require, and the dimmer’s certification must cover the dimming application rather than only the switching function.
• KNX sensors, including push-button interfaces, presence detectors, and brightness sensors, are the input devices through which the occupancy and daylight signals enter the bus, and their certification must demonstrate the correct implementation of the sensor’s data-point types and the KNX Secure communication where the device supports it.
• KNX gateways and interfaces are the devices that connect the KNX bus to other protocols and to the IP network, and their certification scope includes the KNX stack and the physical layer where the gateway routes between KNX lines, alongside the PSTI and ETSI EN 303 645 requirements where the gateway is a connectable product.
• KNX system controllers are the devices that store the project database, execute the logical functions, and provide the visualisation, and their certification follows the same interworking route while the system-level functionality depends on the ETS engineering tool rather than on the controller’s certificate alone.
By Communication Medium
• Twisted pair is the dominant communication medium for KNX lighting control because the bus cable carries both the data at 9.6 kbaud and the 30 V DC power supply, and the physical-layer certification under the KNX accredited laboratory scope verifies the link-layer physical performance that a large installation with long bus runs requires.
• Radio frequency is used where the bus cable cannot be installed, and the KNX RF devices must satisfy the same interworking certification as the twisted-pair devices alongside the radio-equipment conformity requirements of the destination market. Powerline communication is a niche medium that uses the existing mains wiring, and its certification follows the same KNX interworking route while the physical-layer testing is specific to the powerline channel.
• IP/Ethernet is the fastest-growing medium because it is the route through which KNX connects to the building management system and the wider network, and the KNX IP router and interface are the devices that carry this traffic, with the KNX Secure certification and the PSTI statement of compliance applying to the IP-connected devices in a way that the pure bus devices do not face.
Don't pay for what you don't need. Save 30%
Customise your report by selecting specific countries or regions
By Control Function
• Lighting control is the anchor function of the KNX lighting-control market, and the EPBD’s automatic lighting control requirement and ASHRAE 90.1-2025’s expanded daylight and occupancy provisions are the regulatory drivers that make the KNX lighting-control function a code-compliance component rather than a convenience feature.
• HVAC control is a separate function that KNX supports through the same bus, and while the EPBD’s BACS threshold is based on HVAC capacity, the lighting-control requirement attaches to the building because of the HVAC threshold rather than independently, which means the KNX installation that serves the lighting function is often the same installation that delivers the BACS compliance.
• Shading control is a third function that KNX integrates, and the shading actuators and sensors must satisfy the same KNX certification as the lighting devices.
• Energy management and integrated building automation are the functions through which the KNX installation exposes its data to the building management system, and the KNX IP interface and the KNX Secure gateway are the devices that carry this data, with the EPBD’s continuous monitoring requirement and the ISO 52120-1 BACS classification framework determining the functional level that the installation must demonstrate.
By Application
• Residential buildings use KNX lighting control for room-level scene control, dimming, and integration with shading and HVAC, and the certification requirement is the KNX interworking certificate alongside the CE marking for the European market and the BIS registration for the Indian market.
• Commercial buildings are the largest specification-driven segment because the EPBD’s automatic lighting control requirement and ASHRAE 90.1-2025’s control zoning requirements apply to office, retail, and mixed-use spaces, and the KNX installation must demonstrate the zoned control and occupancy detection that the code assumes.
• Hospitality applications use KNX for guest-room control and public-area lighting, and the KNX certification covers the room controller and the sensors, while the PSTI requirement applies to the connectable gateway that links the guest-room system to the hotel’s network.
• Industrial buildings use KNX for lighting control in production and warehouse areas, and the certification requirement follows the same KNX interworking route, with the additional consideration of the electromagnetic environment that the EN 50090-2-2 EMC conformity addresses.
• Institutional buildings, including schools, hospitals, and government facilities, are shaped by the same code requirements as commercial buildings, and the public-procurement channel adds the requirement for the KNX certificate and the regional conformity file to be verified before the system is accepted.
By End-user
• Homeowners are the end-user segment for residential KNX installations, and the procurement is mediated by the certified KNX integrator who programmes the system in the ETS engineering tool, which means the KNX certificate is the evidence that the devices will interoperate with the integrator’s existing toolchain.
• Building owners are the largest specification-driven end-user segment because the EPBD’s BACS requirement and ASHRAE 90.1-2025’s lighting control requirements attach to the building rather than to the device, and the building owner relies on the KNX certificate to demonstrate that the installed system can deliver the zoned control and occupancy detection that the code requires.
• Facility managers operate the installed system and depend on the KNX Secure gateway and the PSTI statement of compliance to demonstrate that the building’s network-connected lighting control is secure, and the KNX diagnostic and monitoring functions provide the data that the EPBD’s continuous monitoring requirement expects.
• System integrators are the channel through which KNX products reach the project, and the integrator’s KNX certification and ETS toolchain determine which products can be commissioned, which means the manufacturer’s KNX certificate is a condition of the integrator’s ability to include the device in a project.
• Building automation contractors operate at the interface between the KNX bus and the building management system, and the KNX IP interface and gateway are the devices through which the contractor integrates the lighting control with the wider BACS, with the KNX Secure and PSTI evidence determining whether the integration can be accepted by the building’s IT security review.
Regional Analysis • Europe operates under the EPBD 2024, with Article 13(12) requiring automatic lighting controls that are suitably zoned and capable of occupancy detection in non-residential buildings above 290 kW and above 70 kW by the end of 2029, and with the BACS requirement assessed against the EN ISO 52120-1 functional classes, alongside the CENELEC EN 50090 and CEN EN 13321-1 standards as the European basis for KNX and the CE marking and EN 50090-2-2 EMC conformity as the market-access requirements.
• North America operates under ANSI/ASHRAE 135 as the US standard that KNX satisfies, and under ASHRAE 90.1-2025, which strengthens lighting control requirements through expanded daylight-responsive controls, stricter automatic shutoff, and more granular control zoning, with the KNX certification providing the interoperability evidence for the multi-vendor installations that the code’s zoning and occupancy requirements assume.
• China operates under GB/T 20965, the Chinese national standard that was translated from the KNX standard through SAC TC124 and adopted in 2007, which makes KNX the only open building-control standard with a Chinese national standard status, and the CCC or CQC certification for the electrical safety of the lighting-control product applies alongside the GB/T 20965 conformity, with the KNX Association maintaining accredited test laboratories in China to serve the domestic certification demand.
• India operates under the BIS registration framework for the electrical portion of the KNX device, and while there is no India-specific KNX standard, the ISO/IEC 14543-3 and EN 50090 basis of the protocol is recognised, and the certified KNX integrator is the channel through which the system is commissioned in the ETS tool, which means the KNX certificate is the evidence that the device will work within the integrator’s toolchain.
• The United Kingdom operates under the PSTI Regulations 2023 for connectable KNX gateways and IP interfaces, with ETSI EN 303 645 deemed compliance and a published statement of compliance defining the support period and the vulnerability-reporting contact, alongside the UKCA marking for the electrical-safety and EMC aspects of the device.
• The Gulf and broader Middle East operate under national building-code and smart-building frameworks that increasingly reference the EPBD and ASHRAE 90.1 principles, with SASO and ESMA certification for the electrical portion of the KNX device and with the KNX certificate providing the interoperability evidence for the multi-vendor installations that the region’s giga-projects specify.
• Australia and New Zealand operate under the SA/SNZ ISO/IEC TS 14543.3 series, which adopts the KNX standard as the national technical specification, alongside the RCM marking for the electrical and EMC aspects of the device.
Considered in this report
• Historic Year: 2020
• Base year: 2025
• Estimated year: 2026
• Forecast year: 2031
Aspects covered in this report
• Global KNX products & lighting control Market with its value and forecast along with its segments
• Various drivers and challenges
• On-going trends and developments
• Top profiled companies
• Strategic recommendation
By Product Type
• KNX Switches & Actuators
• KNX Dimmers
• KNX Sensors
• KNX Gateways & Interfaces
• KNX System Controllers
By Communication Medium
• Twisted Pair
• Radio Frequency
• PowerlineIP/Ethernet
By Control Function
• Lighting Control
• HVAC Control
• Shading Control
• Energy Management
• Integrated Building Automation
One individual can access, store, display, or archive the report in Excel format but cannot print, copy, or share it. Use is confidential and internal only. License information
One individual can access, store, display, or archive the report in PDF format but cannot print, copy, or share it. Use is confidential and internal only. License information
Up to 10 employees in one region can store, display, duplicate, and archive the report for internal use. Use is confidential and printable. License information
All employees globally can access, print, copy, and cite data externally (with attribution to Bonafide Research). License information