Global Emergency Lighting Batteries Market Outlook, 2031

Global Emergency Lighting Batteries Market gains from European industrial-battery rules and recycled-content thresholds from 2031.

Market Insights The global emergency lighting battery market is a certification-driven component market in which product acceptance depends on battery safety, performance under discharge conditions and compliance with the standards governing the complete emergency lighting system. The regulatory framework differs between self-contained emergency luminaires and central battery systems. IEC 60598-2-22:2021, the fifth edition of the emergency lighting luminaire standard, introduced specific requirements for lithium batteries and electric double-layer capacitors. The 2025 BS EN 60598-2-22 update strengthened these requirements by mandating conformity with IEC 62620 and IEC 62133-2. Products holding Kitemark certification had to be updated by the withdrawal date of 24 June 2025. The required battery assessments cover case stress at high ambient temperatures, external short circuits, overcharging and marking under IEC 62133-2. IEC 62620 addresses battery designation, discharge performance at +25°C and low temperatures, high-rate permissible current, internal resistance and storage endurance at constant voltage. The update also added lithium iron phosphate, lithium nickel manganese cobalt oxide and lithium titanate oxide to Annex A. For replaceable batteries, it introduced protection-device requirements covering over-discharge, discharge overcurrent and overcharge. Where two or more cells are connected in series, individual cell-voltage monitoring is also required. Central battery systems follow EN 50171:2021, including its 2022 corrigendum. The standard requires batteries with a design life of at least 10 years at 20°C and specifies that 80% of withdrawn capacity must be restored within 12 hours. Battery sizing must include a 25% aging reserve, based on an assumed annual capacity loss of up to 2.5% for a properly operated lead-acid battery over ten years. The end of service life is reached when the battery's rated voltage under the rated load falls below 90%.

North American requirements focus on equipment listing and emergency operating performance. UL 924 requires battery-equipped emergency luminaires to be listed. The 2026 NEC revision to Section 700.12(G)(1) clarifies that battery-equipped lamps not directly wired to the branch circuit are not considered battery-equipped emergency luminaires. This prevents user-replaceable lamps with internal batteries from being treated as compliant emergency lighting solely on the basis of their discharge capability. NFPA 101 requires a 30-second functional test at least once every 30 days and an annual 90-minute discharge test, with written records maintained for compliance. Battery chemistry and capacity requirements vary significantly by market. China's GB 17945-2024, effective 1 May 2025, prohibits cobalt lithium, nickel-cobalt-manganese lithium and other cobalt-containing lithium-ion chemistries in fire emergency lighting and evacuation indication systems. Lithium iron phosphate is permitted. The standard caps lithium-ion central power supplies at 0.5 kWh and lead-acid, nickel-cadmium and nickel-metal-hydride central power supplies at 5 kWh to reduce thermal-runaway risk. The EU Battery Regulation 2023/1542 introduces recycled-content thresholds from 18 August 2031 for industrial batteries with a capacity above 2 kWh. Minimum recycled-content requirements are 16% for cobalt, 85% for lead, 6% for lithium and 6% for nickel recovered from manufacturing or post-consumer waste. Documentation must be maintained for each battery model, year and manufacturing plant. Saudi Arabia requires lithium batteries used in emergency lighting to comply with SASO IEC 62619. Requirements include overcharge and over-discharge protection, a cycle life of at least 500 cycles and no leakage at 85°C. The battery safety report forms part of the SABER clearance documentation, and the absence of an IEC 62619 report can result in the return of the full shipment.

What's Inside a Bonafide Research`s industry report?

A Bonafide Research industry report provides in-depth market analysis, trends, competitive insights, and strategic recommendations to help businesses make informed decisions.

Download Sample


Competition in the emergency lighting battery market is shaped by certification coverage, battery chemistry and performance under long-term charging and high-temperature conditions. Suppliers must address the requirements of IEC 60598-2-22, EN 50171, UL 924, China's GB 17945-2024, Saudi SASO IEC 62619 and the EU Battery Regulation. Certification coverage is a key supplier-selection factor because the standards address different applications and cannot automatically replace one another. Lithium battery packs intended for industrial applications must meet IEC 62620 performance requirements and IEC 62133-2 safety requirements. The BS EN 60598-2-22 update requires compliance with specified clauses of both standards rather than relying only on a general IEC 62620 test report. Products intended for China must also meet GB 17945-2024 chemistry and capacity restrictions. Chemistry selection determines the markets a supplier can serve. Lead-acid remains an established option for central battery systems because it can achieve the EN 50171 10-year design life when properly sized, and its recycling infrastructure is mature. The EU's 85% recycled-lead threshold from 2031 is also supported by established secondary lead supply. However, China prohibits lead-acid batteries in self-contained emergency luminaires and limits lead-acid central power supplies to 5 kWh. Nickel-metal hydride batteries, governed by IEC 61951-2, provide an alternative for high-temperature applications. They are also permitted under GB 17945-2024 for central power supplies up to 5 kWh, making them relevant where the 0.5 kWh lithium capacity limit is restrictive. Lithium iron phosphate is gaining importance because it is the permitted lithium chemistry under GB 17945-2024 and offers longer cycle life and lower maintenance than lead-acid. However, the Chinese capacity limit and the EU's future recycled-content requirements create additional sizing and documentation obligations. Battery durability is another competitive factor. Emergency lighting batteries remain on permanent float charge, often in elevated ambient temperatures. The EN 50171 aging reserve assumes capacity loss of up to 2.5% annually over ten years. Batteries that degrade more quickly may fail the required discharge-duration test before reaching their nominal design life. The high-temperature case-stress requirements under IEC 62133-2 further require suppliers to demonstrate that their batteries can withstand the operating environment.

Market Dynamics Driver: Updated luminaire standards and battery regulations creating compliance-led replacement demand
• The 2025 BS EN 60598-2-22 update and China's GB 17945-2024 have made battery certification and chemistry compliance important drivers of product replacement and procurement.
• The BS EN update requires cells to conform to IEC 62620 and IEC 62133-2. Its 24 June 2025 Kitemark withdrawal date required affected products to be reassessed or removed from the certified list if they did not meet the updated requirements. This changed the approval requirements for suppliers serving the UK and European self-contained luminaire market.
• China's GB 17945-2024 prohibits cobalt-containing lithium chemistries and limits lithium central power supplies to 0.5 kWh. Batteries designed for European markets using cobalt-containing chemistries cannot be transferred directly into the Chinese market without changes to chemistry and certification. Capacity limits may also require redesign of central power supplies.
• The EU Battery Regulation adds another compliance milestone from 18 August 2031. Suppliers must document recycled-content levels and material provenance for each battery model, year and manufacturing plant, making traceability an additional procurement requirement alongside electrical performance.

Challenge: Chemistry restrictions and capacity limits affecting emergency autonomy
• The main market-access challenge is the variation in permitted battery chemistries and capacity limits across major markets. China's GB 17945-2024 prohibits cobalt lithium and nickel-cobalt-manganese lithium chemistries, permits lithium iron phosphate and imposes capacity limits of 0.5 kWh for lithium central power supplies and 5 kWh for lead-acid, nickel-cadmium and nickel-metal-hydride central power supplies.
• These limits can conflict with the autonomy requirements of larger facilities. A system requiring extended backup duration may not be able to use a lithium central power supply above the permitted capacity. Designers may need to select lead-acid or nickel-based batteries within the 5 kWh limit or distribute backup capacity across multiple self-contained luminaires. Suppliers offering only lithium chemistry may therefore be excluded from certain Chinese central-system applications.
• The EU Battery Regulation introduces a separate documentation challenge. From 2031, suppliers must demonstrate the required recycled shares of cobalt, lead, lithium and nickel for each battery model, year and manufacturing plant. Suppliers sourcing cells from multiple locations may face additional traceability requirements.
• Thermal performance also remains a technical constraint. Batteries must withstand permanent float charging and elevated ambient temperatures. A battery that passes electrical tests but fails the high-temperature case-stress requirement under IEC 62133-2 may not meet the applicable luminaire standard.

Make this report your own

Have queries/questions regarding a report

Take advantage of intelligence tailored to your business objective

Reecha Roy

Reecha Roy

Research Analyst



Trend: Lithium iron phosphate adoption and greater focus on battery provenance
• Emergency lighting batteries are increasingly incorporating lithium iron phosphate, while regulatory requirements are expanding beyond electrical performance to include safety testing and material traceability.
• The BS EN 60598-2-22 update added lithium iron phosphate, lithium nickel manganese cobalt oxide and lithium titanate oxide to Annex A and requires cells to meet IEC 62620 and IEC 62133-2. This brings lithium battery technologies more clearly within the emergency lighting standard's requirements.
• China's GB 17945-2024 permits lithium iron phosphate while prohibiting cobalt-containing lithium chemistries. Its 0.5 kWh capacity cap limits the use of lithium central power supplies to smaller systems, but allows the chemistry to serve self-contained and selected central applications.
• The EU Battery Regulation's recycled-content requirements from 2031 add material provenance to the battery supplier's compliance responsibilities. Suppliers able to provide recycled-content documentation alongside IEC 62620 and IEC 62133-2 test reports will be better positioned to meet these requirements.

Segmentation Analysis By Battery Chemistry
• Lead-acid batteries remain the established chemistry for central battery systems because a properly sized vented lead-acid battery can achieve the EN 50171 10-year design life at 20°C. Mature recycling infrastructure also supports its use. However, China's GB 17945-2024 prohibits lead-acid batteries in self-contained luminaires and limits lead-acid central power supplies to 5 kWh.
• Nickel-cadmium batteries serve specialised high-temperature and high-reliability applications because they are more tolerant of abuse than lead-acid batteries. The EU Regulation's recycling efficiency target of 80% for nickel-cadmium batteries by the end of 2025 reflects the established recycling route, although regulatory pressure on cadmium has limited the segment's future prospects.
• Nickel-metal hydride batteries, governed by IEC 61951-2, serve high-temperature self-contained luminaires and have stated service lives of 300 to 1,000 cycles. They are also permitted for Chinese central power supplies up to 5 kWh, making them an alternative where lithium iron phosphate's 0.5 kWh limit is restrictive.
• Lithium-ion batteries, particularly lithium iron phosphate, are gaining importance because of their longer cycle life and lower maintenance requirements compared with lead-acid. Lithium iron phosphate is the permitted lithium chemistry under GB 17945-2024, although the Chinese capacity cap and EU recycled-content requirements create additional constraints.

By Battery Type
• Sealed batteries are the dominant configuration for self-contained emergency luminaires. Their construction helps prevent electrolyte leakage and allows installation inside the luminaire housing without dedicated ventilation. The BS EN 60598-2-22 update requires over-discharge, discharge overcurrent and overcharge protection, which must be incorporated into the battery or control gear.
• Vented batteries are used in central battery systems where the battery is housed in a dedicated, ventilated room. Lead-acid batteries can meet the EN 50171 10-year design life and 80% recharge within 12 hours when maintained under the specified operating conditions. Their installation requires suitable ventilation and hydrogen-dissipation arrangements.

Don't pay for what you don't need. Save 30%

Customise your report by selecting specific countries or regions

Specify Scope Now
Reecha Roy


By Capacity
• Low-capacity batteries serve self-contained luminaires and exit signs, where each battery provides backup power for an individual fixture. Their capacity is constrained by the physical size of the luminaire and the required operating duration, generally 90 minutes to three hours in the source material.
• Medium-capacity batteries serve small central battery systems and larger self-contained installations. Their sizing must account for the EN 50171 25% aging reserve over ten years rather than only the initial connected load.
• High-capacity batteries are used in central battery systems for hospitals, high-rise buildings and transport infrastructure. They must meet the EN 50171 requirements for 10-year design life and 80% recharge within 12 hours. China's GB 17945-2024 limits central power supplies to 5 kWh for lead-acid, nickel-cadmium and nickel-metal-hydride batteries and 0.5 kWh for lithium batteries.

By Application
• Emergency luminaires represent the largest application segment because self-contained fixtures require batteries to provide backup illumination during power failures. The batteries must meet IEC 60598-2-22:2021 and the BS EN update's IEC 62620 and IEC 62133-2 requirements. The 24 June 2025 Kitemark withdrawal date also changed the certification requirements for affected products.
• Exit signs use low-capacity batteries to maintain visibility during power interruptions. In North America, UL 924 listing applies to battery-equipped emergency luminaires, while NFPA 101 specifies monthly functional testing and an annual 90-minute discharge test. NEC 700.12(G)(1) also establishes the direct-wiring requirement for battery-equipped emergency luminaires.
• Central battery systems use larger vented or sealed batteries to supply multiple emergency lighting fixtures. Their performance is governed by EN 50171, including the 10-year design life, 80% recharge within 12 hours and 25% aging reserve. Battery selection has a direct influence on the system's service life and capital cost.
• Emergency lighting inverters use batteries to supply DC power during an outage. Capacity is determined by the inverter load and required backup duration. EN 50171 requirements apply to the battery within the central power supply system rather than to the inverter alone.

By End-user
• Commercial buildings, including offices, retail and hospitality facilities, represent a major end-user segment because emergency lighting is required for safe evacuation. Battery selection depends on whether the building uses self-contained luminaires with sealed batteries or central systems with larger batteries.
• Industrial facilities use central battery systems where high-mounted luminaires make individual battery maintenance expensive. The EN 50171 10-year design life can reduce maintenance requirements in warehouses and manufacturing facilities where access equipment is costly.
• Healthcare facilities have demanding reliability requirements because emergency lighting must remain available during generator testing and power transfer. The Joint Commission requires documented monthly 30-second functional tests and annual 90-minute discharge tests, making battery reliability important to life-safety operations.
• Transportation infrastructure and government and public infrastructure use central battery systems where emergency loads are large and maintenance access may be difficult. Public procurement can also introduce certification and domestic-content requirements.

Regional Analysis • Europe operates under the updated BS EN 60598-2-22 requirements, including the 24 June 2025 Kitemark withdrawal date and mandatory conformity with IEC 62620 and IEC 62133-2. The requirements cover high-temperature case stress, external short circuits and overcharging for lithium batteries. Central battery systems follow EN 50171:2021, including the 10-year design life at 20°C, 80% recharge within 12 hours and 25% aging reserve. The EU Battery Regulation 2023/1542 introduces recycled-content thresholds from 18 August 2031 for industrial batteries above 2 kWh: 16% cobalt, 85% lead, 6% lithium and 6% nickel recovered from manufacturing or post-consumer waste.
• North America follows UL 924 for battery-equipped emergency luminaires. The 2026 NEC revision to Section 700.12(G)(1) clarifies that battery-equipped lamps not directly wired to the branch circuit do not qualify as battery-equipped emergency luminaires. NFPA 101 requires a 30-second monthly functional test and an annual 90-minute discharge test, with records maintained.
• China's GB 17945-2024, effective 1 May 2025, prohibits cobalt-containing lithium chemistries and permits lithium iron phosphate. It caps lithium central power supplies at 0.5 kWh and lead-acid, nickel-cadmium and nickel-metal-hydride central power supplies at 5 kWh. The standard also prohibits lead-acid batteries in self-contained luminaires and lithium-ion batteries in B-type central power supplies.
• India's BIS framework requires registration under the Compulsory Registration Scheme for the control gear. IS 15885 (Part 2/Sec 13):2012 provides the safety standard for DC- or AC-supplied electronic control gear for LED modules. Batteries installed within luminaires are covered by the luminaire's BIS certification rather than requiring separate battery registration.
• Saudi Arabia requires SASO IEC 62619 compliance for lithium batteries used in emergency lighting. Requirements include overcharge and over-discharge protection, a minimum cycle life of 500 cycles and no leakage at 85°C. The battery safety report forms part of the SABER clearance documentation, and missing IEC 62619 evidence can result in full-batch return.
• Japan applies PSE certification under the Electrical Appliance and Material Safety Act to the electrical portion of the luminaire. The battery installed within the luminaire is covered by the luminaire's PSE certification rather than a separate battery mark.
• Australia follows the RCM marking framework and AS/NZS 60598.2.22 for emergency luminaires. The battery installed within the luminaire is included in the luminaire's compliance documentation rather than requiring standalone battery certification.

Considered in this report
• Historic Year: 2020
• Base year: 2025
• Estimated year: 2026
• Forecast year: 2031

Aspects covered in this report
• Global Emergency Lighting Batteries Market with its value and forecast along with its segments
• Various drivers and challenges
• On-going trends and developments
• Top profiled companies
• Strategic recommendation

By Battery Chemistry
• Lead-Acid
• Nickel-Cadmium
• Nickel-Metal Hydride
• Lithium-Ion

By Battery Type
• Sealed Batteries
• Vented Batteries

By Capacity
• Low Capacity
• Medium Capacity
• High Capacity

By Application
• Emergency Luminaires
• Exit Signs
• Central Battery Systems
• Emergency Lighting Inverters

By End-user
• Commercial Buildings
• Industrial Facilities
• Healthcare
• Transportation
• Government & Public Infrastructure

Request Table of Contents

First Name

Last Name

Company Name

Job Title

Business Email

Contact Number

Description
Logo

Global Emergency Lighting Batteries Market Outlook, 2031

ChatGPT Summarize Gemini Summarize Perplexity AI Summarize Grok AI Summarize Claude Summarize

Contact usWe are friendly and approachable, give us a call.