Loading Bonafide Research

Global Human-Centric Lighting Market Outlook, 2031

Global Human-Centric Lighting Market gains as WELL v2 requires 275 equivalent melanopic lux at workstations.

The global human-centric lighting market is shaped by lighting technologies, spectral measurement methods and building standards designed to support visual comfort, wellbeing and circadian rhythms. Unlike conventional lighting, which primarily focuses on visual illumination, human-centric lighting considers the intensity, colour temperature and spectral characteristics of light throughout the day. CIE S 026:2018 established the α-opic measurement framework for quantifying how optical radiation stimulates five photoreceptor classes in the human retina. Its melanopic channel is particularly relevant to circadian lighting because it measures stimulation associated with intrinsically photosensitive retinal ganglion cells that influence the body's circadian clock. Melanopic Equivalent Daylight Illuminance (M-EDI or mel-EDI) expresses the equivalent illuminance of CIE Standard Illuminant D65 required to produce the same melanopsin stimulus. Unlike conventional photopic illuminance, it accounts for the spectral composition of light and is measured vertically at the eye rather than horizontally on a desk.

The CIE recommends daytime melanopic EDI of at least 250 lux at the eye, preferably achieved through daylight. WELL Building Standard v2 incorporates circadian lighting requirements through its Light concept. Its L03 feature uses equivalent melanopic lux (EML) thresholds, with the supplied framework identifying a 275 EML full-credit threshold at workstations in regularly occupied spaces. The Q2 2025 revision provides flexibility in reference values, requiring the minimum to be achieved for four consecutive hours beginning no later than noon. UL 24480, the Design Guideline for Promoting Circadian Entrainment with Light for Day-Active People, uses the circadian stimulus (CS) metric. It recommends CS of at least 0.3 at the eye for a minimum of two hours daily, preferably in the morning, and dim light below CS 0.1 at night. The US General Services Administration's P100 facilities standard translates this approach into a requirement for occupants to receive CS ≥ 0.3, 240 EML or 400 photopic lux on the vertical plane at the eye for at least two hours daily, preferably in the morning. European standards and building regulations are at a different stage of development. EN 12464-1:2021, which governs indoor workplace lighting, does not establish a normative melanopic requirement for circadian entrainment. Its conventional workplace illuminance level of 500 lux does not automatically provide circadian-effective lighting. Published analysis indicates that at least 218 melanopic EDI at eye height would be required for good daytime melatonin suppression, although the standard does not mandate this level.

What's Inside a Bonafide Research`s industry report?

A Bonafide Research industry report provides in-depth market analysis, trends, competitive insights, and strategic recommendations to help businesses make informed decisions.

Download Sample
The EU Energy Performance of Buildings Directive (EPBD) 2024 includes lighting within Indoor Environmental Quality and recognises human-centric lighting as an important component of healthy buildings. Article 13(12) requires automatic lighting controls that are suitably zoned and capable of occupancy detection. LightingEurope recommends interpreting suitable zoning according to occupant activities rather than simply aligning lighting zones with broader Building Automation and Control System (BACS) zones. China's GB/T 50034-2024, effective 1 August 2024, introduces requirements to consider both visual and non-visual lighting effects. It encourages effective daylight use in workplaces where people spend extended periods, recommends adjustable colour and brightness control where appropriate, and sets a Stroboscopic Visibility Measure (SVM) limit of 1.3 for rooms used for long-duration work. Singapore's Green Mark 2026 gives additional certification importance to DALI-2 or Matter tunable-white support and documented correlated colour temperature (CCT) schedules. These schedules include programmed colour-temperature changes between 2700K and 5000K across the day, making control functionality part of the building assessment process.

Tunable white is a hardware capability that allows a fixture to adjust its colour temperature through multiple LED channels. Circadian lighting, however, requires a verified melanopic outcome at the occupant's eye, supported by an appropriate lighting schedule and intensity. Therefore, a fixture offering adjustable CCT does not automatically qualify as a complete circadian lighting solution. DALI-2 DT8 certification under IEC 62386-209 provides standardised colour-temperature control across manufacturers. DiiA expanded the DALI-2 certification scope to include tunable-white control, with the first certified drivers listed in its product database in 2020. DT8 enables brightness and CCT control through a single address, whereas DT6 uses two addresses. However, protocol certification does not guarantee dimming depth, flicker performance or colour quality across the full CCT range. Output, CRI and colour consistency must therefore be specified separately. Supplier differentiation also depends on the ability to provide eye-level melanopic calculations for specific lighting layouts. WELL L03 uses vertical measurement at 1.2 metres above the finished floor, facing forward to represent the occupant's view. The supplied scoring framework identifies one-point achievement at 150 EML or 136 m-EDI and three-point achievement at 250 m-EDI. Suppliers unable to demonstrate the required performance through layout-specific calculations may face difficulties in WELL-oriented projects, irrespective of their driver certification. Photobiological safety is another important consideration. IEC 62471 and IEC/TR 62778 provide frameworks for assessing blue-light hazards. Manufacturers of high-melanopic lighting products must demonstrate that their equipment remains within the applicable exempt or low-risk classification for the intended exposure duration.

Market Dynamics Driver: Growing adoption of measurable circadian lighting in building certification
• The adoption of melanopic EDI across CIE recommendations, WELL v2, UL 24480 and GSA P100 is moving human-centric lighting from a qualitative design concept towards measurable performance requirements. These frameworks provide lighting designers and manufacturers with reference metrics for developing and documenting circadian-effective installations.
• The CIE's daytime recommendation of 250 lux melanopic EDI, WELL's circadian thresholds and the GSA P100's requirement for CS ≥ 0.3 or equivalent lighting performance create demand for systems that can deliver and demonstrate the required exposure. Singapore's Green Mark 2026 further strengthens this demand by recognising DALI-2 and Matter tunable-white support alongside documented daily CCT schedules.
• China's GB/T 50034-2024 also extends attention towards non-visual lighting effects through its national design requirements and SVM limit, broadening the relevance of human-centric lighting beyond voluntary green-building certification.

Make this report your own

Have queries/questions regarding a report

Take advantage of intelligence tailored to your business objective

Reecha Roy

Reecha Roy

Research Analyst

Challenge: Conflict between circadian lighting targets and energy-efficiency requirements
• A major constraint is the potential conflict between achieving sufficient circadian-effective illumination and complying with lighting energy limits. A 2026 ScienceDirect review reports that electric lighting designed to achieve circadian targets can increase annual energy consumption by up to 300% compared with systems designed only for visual tasks, particularly in deep-plan or poorly daylit spaces.
• ASHRAE 90.1 and International Energy Conservation Code (IECC) lighting power density limits restrict connected lighting loads. The GSA technical report on codes and standards identifies potential conflicts between the P100 requirement for CS ≥ 0.3 over two hours and energy-code lighting power limits. Photosensor-based dimming can also reduce light levels below the circadian target.
• Another challenge is the gap between tunable-white product claims and verified circadian performance. A fixture with adjustable CCT does not necessarily deliver the required melanopic exposure at eye level. Without standardised calculations and supporting documentation in procurement specifications, buyers may find it difficult to distinguish verified circadian installations from conventional tunable-white products.

Trend: Shift towards scheduled, sensor-based and interoperable control architectures
• Human-centric lighting is moving towards dynamic control systems that adjust brightness and colour temperature according to time of day, occupancy and daylight availability. WELL v2's circadian emulation feature allows users to define bed and wake times, with requirements for at least 250 EML during the waking interval and 50 EML or less during the two hours before bedtime.
• Singapore Green Mark 2026 similarly emphasises documented CCT schedules with programmed 2700K–5000K changes and native DALI-2 or Matter support. DALI-2 DT8 and D4i provide interoperable control capabilities, while sensor integration supports automated adjustment based on environmental and occupancy conditions.
• As a result, the value proposition is increasingly shifting from individual tunable-white luminaires towards integrated systems combining scheduling, sensors, control gateways and performance reporting.

Segmentation Analysis By Product Type
• Luminaires are the primary visible product category, but their value in human-centric applications depends on their ability to deliver the required melanopic output across the programmed lighting schedule. Performance is assessed at the occupant's eye rather than through CCT range alone.
• Lighting control systems manage brightness, colour temperature, scheduling and daylight integration. They determine whether the installation achieves the intended circadian exposure and support compliance with building certification requirements.
• LED modules and light sources determine the spectral characteristics and melanopic daylight efficacy ratio of the lighting system. CIE S 026 enables designers to evaluate the melanopic effectiveness of a particular light spectrum rather than relying solely on CCT.
• Sensors provide daylight and occupancy information for automated lighting adjustments. DALI-2 Part 304 addresses light sensors, while Part 303 covers occupancy sensors, supporting interoperability within connected lighting systems.
• Software and services include lighting design, commissioning, melanopic calculations and compliance documentation. These capabilities help demonstrate performance against WELL, UL 24480 and GSA P100 requirements.

Don't pay for what you don't need. Save 30%

Customise your report by selecting specific countries or regions

Specify Scope Now
Reecha Roy
By Lighting Technology
• Tunable White LED is the leading technology in human-centric lighting because it allows colour temperature to shift across the day through warm and cool LED channels. However, manufacturers must maintain acceptable output, CRI, TM-30 Rf and colour consistency across the full CCT range.
• Colour-Tunable LED provides broader colour control and is used in applications where circadian lighting is combined with scene-setting and ambient effects. Its role is comparatively specialised because circadian performance can generally be achieved through white-light tuning.
• Static White LED remains widely used in conventional lighting applications. It can support human-centric designs when its spectral characteristics deliver the required melanopic output, although the absence of dynamic tuning limits its ability to adjust lighting for different times of day.
• Other technologies include specialised and emerging lighting solutions used in research and niche applications.

By Control System
• Manual Control allows occupants to adjust brightness and colour temperature according to personal preference. However, it cannot reliably guarantee a required circadian exposure because performance depends on user behaviour.
• Automated Control uses programmed schedules to adjust lighting intensity and CCT throughout the day. It supports time-based lighting requirements under WELL and Singapore Green Mark frameworks.
• Sensor-Based Control combines programmed schedules with daylight and occupancy inputs. It allows lighting systems to respond to changing environmental conditions and supports the EU EPBD requirement for automatic controls that are suitably zoned and capable of occupancy detection. DALI-2 Parts 303 and 304 provide standardised interfaces for occupancy and light sensors.

By Application
• Residential applications include bedrooms and multifamily housing, where circadian lighting schedules can support daytime activity and lower evening light exposure. WELL's circadian emulation feature provides reference thresholds of 250 EML during waking hours and 50 EML or less during the two hours before bedtime.
• Commercial applications, particularly offices and workplaces, are strongly influenced by WELL, Green Mark and GSA P100 requirements. Lighting designs focus on daytime melanopic exposure, employee comfort and automated lighting schedules.
• Healthcare applications use tunable-white lighting in patient rooms, bedhead panels and clinical environments. Warmer light may be used during evening and night periods, while cooler lighting can support daytime activities and clinical assessment. The primary focus is patient sleep, recovery and wellbeing.
• Education applications consider the relationship between lighting, concentration and learning environments. China's GB/T 50034-2024 also establishes an SVM limit of 1.3 for relevant long-duration work and children's study spaces.
• Industrial applications use human-centric lighting in shift-work environments where alertness, sleep patterns and worker wellbeing are important considerations.
• Hospitality applications focus on guest comfort and wellbeing through dynamic lighting schedules in hotels and other accommodation facilities.

By End-user
• Individual Consumers purchase tunable-white lighting products through retail and online channels. However, verifying circadian performance can be difficult without eye-level melanopic calculations and professional lighting design.
• Corporate Facilities represent a specification-driven segment because WELL and Green Mark certification requirements can influence building-level lighting procurement. Corporate buyers may require documented melanopic calculations and control-system performance.
• Healthcare Providers adopt human-centric lighting in patient-care environments to support sleep quality, comfort and recovery. The lighting specification typically considers the needs of patients, clinical staff and different times of day.
• Educational Institutions use lighting systems designed to support learning environments, concentration and visual comfort. Flicker requirements such as China's SVM limit are also relevant to the specification of lighting in children's study spaces.
• Industrial Operators use scheduled lighting systems in shift-based workplaces where daytime exposure, alertness and sleep quality are relevant operational considerations.

Regional Analysis • Europe follows EN 12464-1:2021 for indoor workplace lighting, although the standard does not establish a normative melanopic requirement for circadian entrainment. The revised EPBD 2024 recognises human-centric lighting within Indoor Environmental Quality, while Article 13(12) requires automatic lighting controls that are suitably zoned and capable of occupancy detection. LightingEurope's guidance on zoning supports activity-based lighting control rather than simply aligning lighting zones with broader building automation systems.
• North America follows a commercially influential framework led by WELL v2, UL 24480 and the GSA P100 facilities standard. WELL's L03 circadian lighting feature uses a vertical melanopic measurement at 1.2 metres, with the supplied scoring framework identifying one-point achievement at 150 EML or 136 m-EDI and three-point achievement at 250 m-EDI. UL 24480 recommends CS ≥ 0.3 at the eye for two hours daily, while GSA P100 requires CS ≥ 0.3, 240 EML or 400 photopic lux on the vertical plane at the eye for at least two hours per day, preferably in the morning.
• China's GB/T 50034-2024, effective 1 August 2024, introduces requirements to consider both visual and non-visual lighting effects. It recommends adjustable colour and brightness control systems where appropriate and establishes an SVM limit of 1.3 for rooms used for long-duration work and children's study environments.
• Singapore's Green Mark 2026 recognises DALI-2 and Matter tunable-white support alongside documented CCT schedules incorporating programmed 2700K–5000K changes. The Building and Construction Authority's assessment criteria include responsive light control and circadian lighting system provisions for new and existing buildings.
• Japan's human-centric lighting development is supported by standardisation activities of the Illuminating Engineering Institute of Japan (IEIJ). Guidance addresses the measurement of non-visual lighting effects, melanopic EDI and indoor lighting recommendations based on international standards.
• India's Energy Conservation Building Code (ECBC) does not currently include a specific circadian lighting requirement. However, its Useful Daylight Illuminance framework and lighting control requirements for daylit areas can support human-centric lighting designs. WELL v2 EML compliance pathways are also used alongside these provisions in Indian green-building projects.
• The Gulf and broader Middle East are influenced by national green-building and building certification frameworks that increasingly reference WELL and CIE S 026 metrics. Hospitality and healthcare projects are important specification channels for tunable-white lighting and circadian scheduling.

Considered in this report
• Historic Year: 2020
• Base year: 2025
• Estimated year: 2026
• Forecast year: 2031

Aspects covered in this report
• Global Human-Centric Lighting Market with its value and forecast along with its segments
• Various drivers and challenges
• On-going trends and developments
• Top profiled companies
• Strategic recommendation

By Product Type
• Luminaires
• Lighting Control Systems
• LED Modules & Light Sources
• SensorsSoftware & Services

By Lighting Technology
• Tunable White LED
• Colour-Tunable LED
• Static White LED
• Other Technologies

By Control System
• Manual Control
• Automated Control
• Sensor-Based Control

By Application
• Residential
• Commercial
• Healthcare
• Education
• Industrial
• Hospitality

By End-user
• Individual Consumers
• Corporate Facilities
• Healthcare Providers
• Educational Institutions
• Industrial Operators

Request Table of Contents

First Name

Last Name

Company Name

Job Title

Business Email

Contact Number

Description

Circadian Lighting/ Human-Centric Lighting Market Research FAQs

Key driver: Growing adoption of measurable circadian lighting in building certification. Key challenge: Conflict between circadian lighting targets and energy-efficiency requirements. Key trend: Shift towards scheduled, sensor-based and interoperable control architectures.

The report uses 2020 as the historic year, 2025 as the base year, 2026 as the estimated year, with forecasts up to 2031.

The Global Human-Centric Lighting Market is analysed by product type (Luminaires, Lighting Control Systems, LED Modules & Light Sources, SensorsSoftware & Services); lighting technology (Tunable White LED, Colour-Tunable LED, Static White LED, Other Technologies); control system (Manual Control, Automated Control, Sensor-Based Control); application (Residential, Commercial, Healthcare, Education, Industrial, Hospitality); end-user (Individual Consumers, Corporate Facilities, Healthcare Providers, Educational Institutions, Industrial Operators).

The report covers Global.

This report is open for pre-booking. Pre-book it to receive the full report as soon as it is released. You can also request a free sample and the table of contents in the meantime.

Yes. Bonafide Research can add countries, segments or company profiles to match your requirements. Request customisation.
Logo

Global Human-Centric Lighting Market Outlook, 2031

ChatGPT Summarize Gemini Summarize Perplexity AI Summarize Grok AI Summarize Claude Summarize

Contact usWe are friendly and approachable, give us a call.